BZQHB - NICAD BATTERY SEALED, CL2123
- MSDS: BZQHB
- Manufacturer: ALEXANDER MFG CO
- Product Name: NICAD BATTERY SEALED, CL2123
- National Stock Number: 6140-00N065264
Product Identification
Product ID:NICAD BATTERY SEALED, CL2123
MSDS Date:12/01/1994
FSC:6140
NIIN:00N065264
MSDS Number: BZQHB
Responsible Party
MASON CITY, IA 50401
US
Emergency Phone: 515-423-8955
Info Phone: 515-423-1161
Cage: 56469
Contractor
Telephone: 515-423-1161/8955
Cage: 56469
Ingredients
NICKEL (SARA 313) (CERCLA) (AND ING 2)
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 20-30%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
NICKEL (II) HYDROXIDE; (NICKEL HYDROXIDE) (SARA 313)
CAS: 12054-48-7
RTECS: QR7040000
Fraction By Weight: 20-30%
OSHA PEL 1 MG/M3 (NI)
ACGIH TLV: 0.1 MG/M3 (NI)
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM (SARA 313) (CERCLA) (AND ING 4)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 13-15%
OSHA PEL 0.2 MG/M3 DUST
ACGIH TLV: 0.01 MG/M3 DUST
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM HYDROXIDE
CAS: 21041-95-2
RTECS: EV1260000
Fraction By Weight: 13-15%
OSHA PEL 0.05 MG/M3 (CD)
ACGIH TLV: 0.05 MG/M3 (CD)
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 2-4%
OSHA PEL 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
GROUP 1.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:UNDER NORMAL USE, BATTERY DOES NOT
RELEASE TOXIC MATERIAL. INHAL:DURING A FIRE INVOLVING LARGE
QUANTITIES OF BATTERIES, CADMIUM FUMES MAY BE RELEASED. EYES/SKIN
CONTACT:IF BATTERY RUPTURES, TRACE AMOU NTS OF POTASSIUM HYDROXIDE,
WILL CAUSE A BURN.
Explanation of Carcinogenicity:NICKEL:IARC MONOGRAPHS ON EVAL OF CARCIN
RISK OF CHEMS TO MAN, VOL 49, PG 257, 1990:GRP 2B. NTP 7TH ANNUAL
RPT (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
First Aid
First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
MD . SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD .
Fire Fighting
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WAREHOUSE OR DEPOT TYPE STORAGE.
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.
Accidental Release
Spill Release Procedures:ELECTROLYTE, POTASSIUM HYDROXIDE IS CAUSTIC.
DO NOT ALLOW SKIN OR EYE CONTACT. FLUSH W/WATER. THERE IS ONLY A
TRACE AMOUNT OF POTASSIUM HYDROXIDE AVAILABLE IN THE BATTERY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Other Precautions:THIS BATTERY DOES NOT RELS/OTHERWISE RESULT IN EXPOS
TO HAZ CHEM UNDER CNDTNS OF YOUR INTENDED USE. EACH CELL OF THE
BATTERY IS A SEALED CONTAINER ENCLOSING A NICKEL ELECTRODE, A
CADMIUM ELECTRODE & P OTASSIUM HYDROXIDE ELECTROLYTE.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Supplemental Safety and Health
EXPLAN OF CARCIN:ON CARCIN, 1994:ANTIC TO BE CARCIN. HUMAN:LUNGS, NASAL
CAVITIES. CADMIUM:IARC MONOGRAPHS, SUPP, VOL 7, PG 139, 1987:GRP
2A. NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC TO BE CARCIN. HUM
AN:LUNG, PROSTATE, RENAL SYSTEM EFFECTS. CADMIUM HYDROXIDE:IARC
MONOGRAPHS ON EVAL OF CARCIN RISK OF CHEMS TO (ING 6)
Stability
Stability Indicator/Materials to Avoid:YES
NO INFO AVAILABLE. BATTERY MAY SHORT CIRCUIT IN WATER.
Stability Condition to Avoid:BURNING (FIRE), RUPTURING.
Hazardous Decomposition Products:CADMIUM FUMES MAY BE RELEASED DURING A
FIRE.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.